Page 1 of 2
Qingxian Zeming Langxi Electronic www.micro-transformer.com
Tel: 86-25-52601870 Fax: 86-25-52633420 E-mail:zm@zeming-e.com
ZMCT102 Current Transformer
Small size,high accuracy,good consistency,for current and power measurement
Structural parameter:
Front view Bottom view
The main technical parameters:
Model ZMCT102
input current 0-20A(100Ω)
Output current 2.5mA at 5A
turns ratio 2000:1
phase angle error
≤20'
(input 1A,sampling resistor 100Ω)
linearity 0.2%(5%dot~120%dot of 5A)
Permissible error
-0.2%≤f≤+0.2%
(input 1A,sampling resistor 100Ω)
application current and power measurement
isolation voltage 4500V
Encapsulation Epoxy
installation PCB mounting(Pin length>3mm)
operating
temperature
-40°C~+85°C
Direction for use:
Page 2 of 2
Qingxian Zeming Langxi Electronic www.micro-transformer.com
Tel: 86-25-52601870 Fax: 86-25-52633420 E-mail:zm@zeming-e.com
Figure I FigureII
1. The typical usage of the product is for the active output ( Figure I) . R is a sampling resistor
2. The product can be directly through the resistance sampling , easy to use ( FigureII).